MMO DSA Coated Titanium Tubular Anode
The tubular can be made singly or in strings, the substrates are using of seamless titanium tubes which meet standard of ASTM B338 in Grade 1 or Grade 2 Chemical Composition.
MMO tubular anodes coating are consisting of Precious Mixed Metal Oxides IrO2-x and Ta2O5, it has been proven to have a good performance within the design life. The coating thicknesses are designed base on application environment and tested by X-Ray and the life span are verifying by Acceleration life test which conducts in Saga’s test laboratory for each batch of goods.
MMO DSA Coated Titanium Tubular Anode
The tubular can be made singly or in strings, the substrates are using of seamless titanium tubes which meet standard of ASTM B338 in Grade 1 or Grade 2 Chemical Composition.
MMO tubular anodes coating are consisting of Precious Mixed Metal Oxides IrO2-x and Ta2O5, it has been proven to have a good performance within the design life. The coating thicknesses are designed base on application environment and tested by X-Ray and the life span are verifying by Acceleration life test which conducts in Saga’s test laboratory for each batch of goods.
Tubular anode is used for the soil, fresh water, sea water and mud, or the other natural environments, it could be used alone or make it a string. Various tubular anode available as requested.
Application
Ground beds: (deep groundbed, Shallow or open hole);
Sea Water;
Brackish Water;
Fresh Water;
Working Environment: Including soil, carbonaceous backfill, fresh water, brackish water, and seawater.
Advantages:
High current output and low electrical resistance;
Using tubular anodes can save 15-35% of install cost comparing to use other anodes;
Anode-cable assemblies are easy to handle, transport and install because of their unique flexibility;
Tubular anode cable are easy to handle, transport and install because of flexibility;
Lower cost per amp;
Guaranteed electrical contract and moisture seal integrity;
Consistently low resistance anode;
CONSTRUCTION
We can supply all required extras for MMO tubular anode:
- Cable with specific length
- Canister with carbonaceous backfill
- Heat shrink caps
- Ropes or suspension assembly
- Centralizers
- Customer’s specific requirement
PHYSICAL PROPERTIES
For Fresh water, Calcined petroleum Coke application:
Anodes Diameter | Length | Current Output | Design Life |
19mm | 1200mm | 7A | 20 years |
25mm | 500mm | 4A | 20 years |
25mm | 1000mm | 8A | 20 years |
25mm | 1200mm | 10A | 20 years |
25mm | 1500mm | 12A | 20 years |
32mm | 1200mm | 12A | 20 years |
For Sea water application:
Length | Current Output | Design Life | |
19mm | 1200mm | 43A | 20 years |
25mm | 500mm | 24A | 20 years |
25mm | 1000mm | 47A | 20 years |
25mm | 1200mm | 57A | 20 years |
25mm | 1500mm | 71A | 20 years |
32mm | 1200mm | 72A | 20 years |
Design current density under different electrolytes:
Electrolytes | Maximum design current density A/M2 | Expected Life |
Carbonaceous backfill | 50 | 20 years |
Calcined petroleum coke | 100 | 20 years |
Fresh water | 100 | 20 years |
Sea water | 600 | 20 years |
Mud | 100-300 | 20 years |
Tubular Anode Cable Selection:
PVDF,HMWPE,HALAR,XLPE,PVC or KYNAR are all optional,
Saga recommends dual-insulated cable, such as PVDF/HMWPE cable for use where anodes operate in groundbeds high in chlorides – resulting in chlorines gas generation. Where chlorides are not anticipated, such as shallow vertical and horizontal surface beds, an economical cable choice is HMWPE. The high current capacity (150 amps) and flexibility of the Exane Rig cable makes it ideal for seawater applications.
Ordering Information:
When ordering tubular anodes from Saga, please specify the following:
- Anode Type (for example, length, diameter…).
- Number of anodes per string.
- Center-to-center spacing between anodes along the cable.
- Cable tail length (above the top anode).
- Total cable length (sum of lengths of anodes, spaces and tail).
- Current output.
- Number of centralizers required and hole size.