MMO Titanium Ribbon anode
MMO Ribbon Anode for Cathodic Protection is designed to provide corrosion protection for Fine sand environments, above ground storage tanks bottoms and reinforced concrete structures, etc.
Applications
Reinforced concrete structures;
Buried steel structures;
Underground and above ground storage tanks;
Buried pipelines.
Working Environment:
Including soil, fresh water, brackish water, and seawater.
The anodes are composed of titanium ribbon substrate coated with a mixed metal oxide catalyst. The anodes can achieve 50 years operating lifespan in a current density of 17mA/m. The mixed metal oxide anodes are designed for protecting the bottoms of many large-scale storage tanks. They can be used in sands with various levels of moisture and salt contents without any carbon filling materials.
MMO meshes or ribbons were welded together by metal titanium current distribution member as impressed-current anodes in storage tanks’ bottoms for cathodic protection system.
MMO Ribbon Anode for Cathodic Protection is designed to provide corrosion protection for Fine sand environments, above ground storage tanks bottoms and reinforced concrete structures, etc.
FEATURES
* Low consumption rate
* Easy installation
* Low maintain cost
* Effective and environmental
* Long working life
CONSTRUCTION
Titanium Conductor Bar usually be used along with the MMO Ribbon Anode, acts as an inert conductor to electrically connect the MMO Ribbon anode, reduces attenuation losses and connects to the positive cable through rod connectors. The Titanium Conductor bar is connected to the MMO Ribbon Anode by spot welds applied at the point of crossover.
PHYSICAL PROPERTIES
MMO Ribbon Anode | ||
Width | 6.35mm(0.25’’) | |
Thickness | 0.635mm(0.025’’) | |
Standard Coil Length | 100m | |
Standard Coil Weight | 1.82kg | |
Surface Area of Ribbon | 0.014 m2 per/m | |
Fine Sand | Current output | 42mA per m(12.8mA/ft) |
Expected life | 50 years | |
Concrete | Current output | 1.5mA per m(0.45mA/ft) |
Expected life | 50 years | |
Titanium Conductor Bar | ||
Width | 12.7mm(0.50’’) | |
Thickness | 0.9mm(0.035’’) | |
Standard Coil Length | 100m | |
Standard Coil Weight | 5.15kg |
Other specification of MMO ribbon anode
Width(mm) | Thickness(mm) | Current Output(mA/m) | Expected Life(Y) |
6.35 | 0.635 | 17 | 50 |
6.35 | 0.635 | 34 | 50 |
12.7 | 0.635 | 68 | 50 |
Applications
Reinforced concrete structures;
Buried steel structures;
Underground and above ground storage tanks;
Buried pipelines.
Working Environment:
Including soil, fresh water, brackish water, and seawater.